Room Temp Cure
Home
New  Systems
Traditional
Epoxy
Polyurethane
Room Temp Cure
Heat Cure
UL 94 VO
Pricing
To Order
Help Page
Applications
Guidelines
Safety & Handling

. For more information contact:
Adhesive
  HotLines
U.S. and Canada
1-800-323-5158
    Fax
1-800-353-7770

 World Wide
01-847-437-7773
    Fax
01-847-437-8006



 To Glu Guru Adhesive Tech Center   

To Adhesive World

To Dymax UV Products

Epoxy

Workin g Life @

Minimum Cure Schedule @ Centigrade

Flame Retarda nt

Typical Applications

Araldite CY 221/
Hardener HY 956 EN/US

60 min

24 hrs @25-36 or 5 hrs @ 60

No

Pressure Sensative components, modules, magnetic elelments, proximity switches.

Araldite CW2243L US/
Hardener HY 2966 US

40 Min

24 hrs @ 25 or
6 hrs @ 60

UL 94 V-O

Voltage regulators, relays, resistor networls,  iron core transformers, modules, proximity switches

Araldite D US/
Hardener HY  956 EN/US

60 Min

25 hrs @ 25 or
3 hrs @ 60

No

Filter circuits, modules, auto sensors, capacitors, iron-core transformers, magnetic head coils

Araldite CW 8704/
Hardener HY 8704

90 Min

24 hrs @ 25 or
2 hrs @60

No

Applications requiring high heat dissipation, bushings

New Generation
Araldite CY 8770/
Hardener HY 8770

23 min
@ 25 C

24 hr @ 25*

No

Switches, modules, sensors, filters, capacitors

New Generation
Araldite CW 8771
Hardener HW 8771

100 min
@ 25 C

24 hr @ 25*

UL 94 V-O

Switches, modules, sensors, filters, capacitors

*Cure schedule results in approxamately 90% properties, additional room temperature is required for 100% properties.

Polyurethane

Workin g Life @

Minimum Cure Schedule @ Centigrade

Flame Retarda nt

Typical Applications

New Generation
Araldite CY 8780
Hardener HY 8780

30  min
@25 C

24 hrs @25*

No

Stress sensitive components, coils, potentiometers, modules with complicated circuitry
 

New Generation
Araldite CY 8781
Hardener HW 8781

60 Min  @ 25 C

24 hrs @ 25*
 

UL 94 V-O

Transformers, filters, capacitors, pressure sensitive devices

New Generation
Araldite CY 8782/
Hardener HW 8782

50 min
@ 25 C

24 hr @ 25*

UL94 V-O

.Transformers, filters, capacitors, pressure sensitive devices
 

New Generation
Araldite CY 8783
Hardener HW 8773

50 min
@ 25 C

48  hr @ 25*

UL 94 V-O

.Transformers, filters, capacitors, pressure sensitive devices
 

*Cure schedule results in approxamately 90% properties, additional room temperature is required for 100% properties.

For More Information Call 1-800-323-5158 or Email   mike@on-hand.com

 