Encapsulating Systems for Electronics 
    Electronics

Home    Adhesive Catalogs       Adhesive Data Sheets    Adhesive Manuals
 

Heat Cure
Home
New  Systems
Traditional
Epoxy
Polyurethane
Room Temp Cure
Heat Cure
UL 94 VO
Pricing
To Order
Help Page
Applications
Guidelines
Safety & Handling

. For more information contact:
Adhesive
  HotLines
U.S. and Canada
1-800-323-5158
    Fax
1-800-353-7770

 World Wide
01-847-437-7773
    Fax
01-847-437-8006



 To Glu Guru Adhesive Tech Center   

To Adhesive World

To Dymax UV Products

Epoxy

Working Life @

Minimum Cure Schedule @ Centigrade

Flame Retardant

Typical Applications

Araldite CW 1277 US/
Hardnener HY 1277 US

8 hrs

2 hrs @ 80+
3 hrs @ 110

UL 94 V-O

High Voltage applications, television transformers,sensors, connectors, capacitors

Araldite CW 1280 US/
Hardener HY 1280 US

16 hrs

2 hrs @ 80+
3 hrs @ 110

UL 94 V-O

High Voltage applications, television transformers,sensors, connectors, capacitors

Araldite 8573/
Hradnener HW 8573

8 hrs

1 hr @ 100

No

High Voltage applications, capacitors, sealants, modules

Araldite CW 2122-1 US
Hardener HY 2901-1 US

8 hrs

3 hrs @ 110 or
6 hrs @ 90

UL 94 V-O

Focus resistors, pressure sensitive devices, transformers, suppressor chokes

Araldite CW 8715/
Hardener HY 8715

20 min

2 hrs @ 80

UL 94 HB

Light weight pressure sensitive devices, modules

Araldite CW 5702 US/
Hardener  HY 5703 US

6 hrs

2.5 hrs @ 90+
2.5 hrs @ 140

No

Car ignition coils, high voltage transformers

Araldite XR 5715/
Hardener Xh 5716

8 hrs

3 hrs @ 85+
2 hrs @ 150

No

Car ignition coils, high voltage transformers

Araldite CW 1195 US/
Hardener HW 1196 US

8 hrs

4 hrs @ 150 or
2 hrs @ 80 +
4 hrs @ 150

UL 94

Power semiconductors (hybrid IGBT)

New Generation
Araldite CW 8772/
Hardener HW 8772

120 min @
25 C

6 hrs @ 60

UL 94 V-O

Switches, modules, sensors, filters, capacitors, transformers, resistors, voltage regulators

New  Generation
Araldite  CW 8773/
Hardener HY 8773

8 hrs @
25  C

6 hrs @ 90
3 hrs @ 110

UL 94 V-O

Sensors, transformers, resistors, voltage regulators

Polyurethane

Working Life @

Minimum Cure Schedule @ Centigrade

Flame Retardant

Typical Applications


Araldite CW 8690
Hardener HW 8691

7 min

1 hr @ 80

No

Auto modules, auto sensors, under-the-hood applications

Special Systems

Working Life @

Minimum Cure Schedule @ Centigrade

Flame Retardant

Typical Applications

Araldite CY 8767
Hardener HY 8767

>10-20 min

30 min @ 65

---

Terminal lead encapsulation and battery housing potting, uninterruptible power supply, sulfuric acid resistant


Araldite CV 5745
(One Component)

---

30 min @ 175

---

Core bonding

For More Information Call 1-800-323-5158 or Email   mike@on-hand.com

 

Copyright © 1999-2007 On-Hand Adhesives, Inc All Rights Reserved   Last modified: August 10, 2007