Encapsulating Systems for Electronics 
    Electronics

Home    Adhesive Catalogs       Adhesive Data Sheets    Adhesive Manuals
 

Optimizing encapsulant performance
Home
New  Systems
Traditional
Epoxy
Polyurethane
Room Temp Cure
Heat Cure
UL 94 VO
Pricing
To Order
Help Page
Applications
Guidelines
Safety & Handling

. For more information contact:
Adhesive
  HotLines
U.S. and Canada
1-800-323-5158
    Fax
1-800-353-7770

 World Wide
01-847-437-7773
    Fax
01-847-437-8006



 To Glu Guru Adhesive Tech Center   

To Adhesive World

To Dymax UV Products

Click on image for large view and use back button to return to page.

GUIDELINES

FOR

OPTIMIZING

ENCAPSULANT

PERFORMANCE


Proper processing is important to achieve optimum system performance after an encapsulating system is selected. Processing an encapsulating system involves three steps:

Preparation of the casting mix
Casting
Gelation and Cure

Casting mix preparation
Before removing encapsulating system components from the container, stir materials thoroughly. This is particularly important for filled systems because filler may show a tendency to settle during storage. In addition, resins with a high filler content should be heated in an oven at 60C to 80C (140F to 178F) in their original containers before mixing.
This procedure will facilitate stirring and pouring. Note: Preheating hardeners is not recommended because of higher vapor pressure.
To combine resin and hardener, mix encapsulating system components with a low viscosity of less than 3,000 cP at room temperature either manually or in an open mixer.
Resin systems with a higher viscosity should be reheated to 40C to 50C (I 04F to 122F) before the room-temperature hardener is added. To improve system uniformity and dielectrical properties, degas the blended casting mix under a vacuum of more than 28 inches of mercury before pouring.

 Casting
 
To cast resin systems with a long work life, pour mixed components by hand or from a batch mixer into an open mold at atmospheric pressure. However, if the encapsulating system has a short work life, or for long production runs, use of continuous-type mixing and metering equipment is preferable,

In many cases, it is advantageous to preheat electronic assemblies to a temperature 20C to 30C higher than the processing temperature of the mix to facilitate part wetting and help remove trapped air.

To prevent foaming under a vacuum, the pressure in the casting chamber
should be  higher than the vacuum used to prepare  individual system components.

Gelatin and Cure
Curing is typically conducted according to the schedule recommended in the product data sheet. Room-ternperature systems cure at about 25C (77F). Depending on the reactivity of the casting mix and the ambient shop temperature, cure. tirne is usually from 12 to 72 hours. The cure cycle of an encapsulating system can be accelerated by postcuring at elevated temperatures.

Heat-cure systems are typically cured at temperatures above 90C (194F). However, some encapsulating systems can be cured at temperatures slightly above 80C (176F). To minimize internal stress, cure encapsulants in two stages, gelation followed by postcuring. This ensures good high temperature and thermal cycling performance.

Note: The exothermic heat liberated during the cure process, especially for room -temperature-cure systems, can produce internal casting temperatures that are significantly higher than the cure temperature of the encapsulating system.

For further details on system handling and mixing contact a technical representative at 1-800-323-5158

 

For More Information Call 1-800-323-5158 or Email   mike@on-hand.com

 

Copyright © 1999-2007 On-Hand Adhesives, Inc All Rights Reserved   Last modified: August 10, 2007